Measuring principle
Resistance Temperature Detector (RTD)
Characteristics / Application
-
Metric design
-
Modular temperature assembly
-
Universal range of applications
-
Suitable for hazardous areas
-
Suitable for high process pressures
-
Equipped with neck or iTHERM QuickNeck
-
Includes thermowell / protection tube (metal) or can be installed into a thermowell
-
Compatible with iTHERM StrongSens
Thermowell / Protection tube
Insert / Probe
Outer diameter protection tube / insert
-
16 mm (0.63")
-
18 mm (0.71")
-
19 mm (0.75")
-
19.5 mm (0.77")
-
20 mm (0.79")
-
22.2 mm (0.87")
-
24 mm (0.95")
-
25 mm (0.98")
-
25.4 mm (1.0")
-
26 mm (1.02")
-
27 mm (1.06")
-
30 mm (1.18")
-
33.4 mm (1.31")
Max immersion length (on request)
Up to 1500 mm (59.06")
Material protection tube / thermowell
-
316 (1.4401)
-
316L (1.4404)
-
316/316L (1.4401/1.4404)
-
316Ti (1.4571)
-
347 (1.4550)
-
310 (1.4841)
-
Alloy 600 (2.4816)
-
Alloy C276 (2.4819)
-
10CrMo9-10 (1.7380)
-
13CrMo4-5 (1.7335)
-
16Mo3 (1.5415)
-
A105 (1.0460)
-
C22.8 (P250GH) (1.0460)
-
P355NH (1.0565)
-
Duplex S32205 (1.4462)
-
Titanium Gr2 (3.7035)
Process connection
-
Male thread: G1", NPT1/2", NPT3/4", NPT1", M14x1.5, M18x1.5, M20x1.5, M27x2, M33x2
-
Female thread: M24x1.5, NPT1/2"
-
Flange: DN25 PN16, PN40, PN50, PN100 B1; DN40 PN40 B1; DN50 PN40, PN63 B1; various ASME flange sizes
-
Weld-in: diameters 18 mm to 33.4 mm
Tip shape
Surface roughness Ra
-
0.76 μm (30 μin)
-
1.6 μm (63 μin)
Operating temperature range
-
PT100 TF iTHERM StrongSens: -50 °C … 500 °C (-58 °F … 932 °F)
-
PT100 TF iTHERM QuickSens: -50 °C … 200 °C (-58 °F … 392 °F)
-
PT100 WW: -200 °C … 600 °C (-328 °F … 1,112 °F)
-
PT100 TF: -50 °C … 400 °C (-58 °F … 752 °F)
-
Type K: max 1,100 °C (2,012 °F)
-
Type J: max 800 °C (1,472 °F)
-
Type N: max 1,100 °C (2,012 °F)
Max process pressure (static)
Up to 500 bar depending on configuration
Accuracy
-
Class AA according to IEC 60751
-
Class A according to IEC 60751
-
Class B according to IEC 60751
-
Special or standard class according to ASTM E230
-
Class 1 or 2 according to IEC 60584-2
Response time
Depending on configuration
Integration head transmitter
Yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex approvals
-
ATEX Ex ec, Ex tc
-
ATEX IECEx Ex ia
-
NEPSI Ex ia
Certifications